500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

Mengchuan Instrument Co,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

Brand Name : MC

Model Number : DF-96D

Certification : ccc

Place of Origin : China

MOQ : 10

Price : USD$8~25/pc

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 1000/pieces per months

Delivery Time : 3-5 work days

Packaging Details : original packing

Working voltage : AC 220V/50HZ

Max Current : 10A(Use the 30A Delay)

Power consumption : ≤2W

transmission signal : 500M

Size : 126*88*51mm

Warranty : 1 year

Contact Now

DF-96D Automatic Water Level Controller Switch 10A 220V Tank Liquid Level Pump Controller

Introduction


This product uses integrated circuit, and combines the high-rise building. The water level of the lower pool (water tower) is designed by grade lifting. It has the functions of joint control of the upper and lower pools, water drainage and water shortage protection. It can automatically realize water refill and drainage of the water tank, and effectively prevent the overflow of the water level of the pool or the damage of the pump idling

Specification



model DF-96D
Dimensions 126×88×74mm
Operating Voltage 220V
Installation method guide
Power consumption ≤2W
load 10A

Installation


Single-control UP pool (water storage) installation instructions shown in figure 1

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

A(red)—Upper water level control point. When water level gets to A point,

the probe touch water and controller can stop the pump by auto.

B(blue)—Lower water level control point. When water level gets off B point,

the probe out of reach water and controller can start the pump by auto.

C(black)—Should be placed in bottom of pool as the common line.

D(green) and E(yellow)are connected with C (black).

Single-control DOWN pool(drain water)installation instructions shown in figure 2.

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

E—Upper water level control point. When water level gets to E point,

the probe touch water and controller can start the pump by auto.

D—Lower water level control point. As liquid level gets off D point,

the probe out of reach water and controller can stop the pump by auto.

C—Should be placed in bottom of pool as the common line.

A&B—disconnected

1 . Lack of water protection installation instructions shown in figure 3.

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

C&D—Lower water level control points. When water level gets off this point,

C or D probe out of reach water and controller can stop the pump by auto.

E&C—short-connected;

A&B—disconnected

2 . Joint control UP and DOWN pool installation instructions shown in figure 4.

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

A—Upper water level control point in UP pool. When water level gets to A point,the probe touch water and controller can stop the pump by auto.

B—Lower water level control point in UP pool. When water level gets off A point, the probe out of reach water and controller can start the pump by auto.

C—Should be placed in bottom of UP and DOWN pools as the common line.

D—Lower water level control point in DOWN pool. When water level gets off D point, the probe out of reach and controller can stop the pump by auto.

E—Upper water level control point in DOWN pool. When water level gets to E point, the probe reach water and controller can start the pump by auto. Then pool starts to drain water. If not, E point disconnected

Performance characteristic


Used to solve problem:

1. On power but no work:

a. Check the red indicator is on or not. If not, make the connection is good enough;

2. When water level is above or below probes but the pump does not start or stop by auto, Please check it like the following.

a. Whether the probe is placed too high or low so that water level can reach or out of reach it;

b. The connection of upper &lower line or probe is dislocation by error or short connected;

c. To check the probe whether it is rust or not or the connection is good enough.

d. C- Check the common line whether it is placed in the lowermost bottom of pool.

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

220V

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm

Market application


It is very suitable for urban and rural schools, industrial and mining enterprises and institutions as well as the water tower well water supply project.

  • printing and dyeing
  • chemical industry
  • food and beverage
  • brewing sugar
  • other industries

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm


Product Tags:

500M automatic water tank controller

      

automatic water tank controller 220V 50Hz

      

500M auto tank water level controller

      
Quality 500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm for sale

500M Signal Automatic Water Tank Controller 10A 220V 50Hz 126*88*51mm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Mengchuan Instrument Co,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)